F-Sorb 3400CE surface area
and pore size analyzer introduction
F-Sorb X400CE series surface area and porosity analyzers
are new generation instruments which were researched and developed by Gold APP
Instruments and China weapons institute. Gold APP Instruments is one
of analytical equipments manufacturers among world suppliers,
our fully-auto and highly intelligent analyzers can match international
standards and trends. Innumerable independently patented techs make Gold APP
instruments enjoys great popularity at home and abroad. A high level of
precision and resolution, complicity of operation, speed, compact size, and
their stability guarantee our analyzers equally appropriate to industry quality
control, institutes, universities and laboratories. The weapons system’s high
demands and imported parts with original packaging had greatly improved
instruments’ reliability and life.
F-Sorb 3400CE adopts speed and
efficient flow gas adsorption principle, not only an expert for
contrast reference materials method and BET method, but also a specialist
for BJH total pore volume and pore size distribution analysis. Excellent cost
performance can assure your investment gains with ease.
F-Sorb 3400CE surface area
and pore size analyzer parameters
Measuring Method: BJH total pore volume, pore area and porosity analysis, contrast
reference materials method, single and multi point BET method, Langmuir
surface area, carbon black surface area (STSA), adsorption constant C.
Measuring Ranges: 0.01 m2/g to no known upper limit (specific
surface area)
2-200nm (pore size)
Accuracy: repeatability errors ≤2%
Traffic Adjust: Gold APP patented F-Sorb micro stepping motor traffic
can realize traffic auto-adjust for every P/Po point in BET
analysis; traffic value auto-collected by software and real-time displayed in
interface
Quantitative Dosing: patented F-Sorb quantitative pipeTM desorbs
automatically, realized auto dosing for sample desorption isotherm, manual
pipeline switch is not required
Manifolds’ Sealing: high vacuum system with stainless steel manifolds, sound
sealing performance can eliminate errors caused by gas molecules permeation
Sample Types: powders, particle, fiber, flakes and other species
Sample Ports: 4 samples simultaneously
Analysis Gases: high purity (99.99%) He as carrier; N2
(99.99%) as adsorbate, Ar, Kr etc. are optional
Time: less than 5 minutes for every P/Po point’s adsorption and
desorption; analysis data will present automated by Gold APP softwareTM
Pressure: atmospheric pressure, no need vacuum, save experiment
time
Data Acquisition: high precision and integration chip, minimal errors,
strong anti-interference ability
Data Reduction: Windows®-base independently developed Gold APP softwareTM,
perfect versatility, ease of use and multi-model data reduction reports (pdf,
word, excel, txt)
Operation System: multifunctional, fully automated, highly intelligent
operation system
Fully
automated and intelligent analyzer; farewell to complex manual operation; minimal
user intervention; promote efficiency; F-Sorb 3400CE had improved a lot besides
F-Sorb 2400CE outstanding features.
A. Structure Design
1.
Stainless manifolds system is much better than plastic manifolds, obviously
enhances sealing performance, eliminates errors caused by gas molecules
permeation, no ageing for manifolds, increase reliability and prolong life,
more appropriate for humid environment.
2.
Modularity structure satisfies customer required configuration and instrument
maintenance.
B. Control System
1.
Integrated multifunctional control system; motor screw rod lifting system
ensures Dewar stable running.
2.
Innovated balanced bridge circuit greatly improves signal voltage sensitivity,
as well as achieves auto balance of signal zero drift.
3.
Fully-auto operation, minimal operator involvement and work efficiency
improved.
C. Data Acquisition and Reduction
1.
High precision data acquisition and signal amplification, high integrated A/D
transformation system, strong anti-interference ability and high real time, can
reduce environmental influence on analysis procedures.
2.
Utilize super sensitive thermal conductivity detection and balance system can
increase detectable signal range; zero drift auto calibration system enhances
stability and accuracy.
3.
Independently innovated Windows® compatible software, versatile
applications, flexible customer-tailor interface, ease of use; self developed
data reduction module can efficiently eliminate system errors and improve
precision.
4.
Customer made data reports and diversified calculation models are convenient
for data analyzing; powerful data archiving and searching capacity helps a lot
for data management.
D. Analysis Optimize
1.
Multi analysis methods, no need to convert operations frequently, all set in
dedicated software.
2. Specific
surface area and porosimetry analysis can switch freely, simplify operation
steps and improve measurement efficiency.
3.
Pioneered sample desorption isotherm integral calibration function for bigger
P/Po, which advances accuracy; innovated gas amount auto-adjust
system brings exactly control for high/low partial pressure in porosity
measurement.
F-Sorb 3400CE surface area
and pore size analyzer application
1.
Super micro powder, nanomaterials, particle and fiber shaped specific surface
area analysis.
2.
Product quality control for powder species related corporations.
3.
Research institutes, universities for BET and BJH theory teaching.
4.
Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials,
energy storage materials etc.
5.
Other researches concern surface area performance.
Contact info:
Email: sales@jinaipu.com
Tel.:
0086-10-82133318 Ext.810
Fax:
0086-10-82118197
Mobile:
0086-18210009838
IMs:
Skype: